This course is designed for oilfield professionals who need to conduct oilfield demulsifier bottle tests using a pre-designed procedure. Field emulsion evaluation using centrifugation method to break total water down to water at various phases in oilfield emulsions is explained in detail. Key bottle test equipment you would need are listed. The demulsifier bottle test procedure is discussed.
Designing a bottle test procedure and best practices of bottle tests are discussed in the Level 2 course.
Course Format:
Online presentation with audio, 50 slides
Course Topics:
Demulsifier bottle testing overview
Key Bottle test equipment – What and Why
A Horizontal Spin Centrifuge
Clear Graduated Conical Bottom 12.5 mL Centrifuge Tubes
A Water Bath with Adjustable Temperature
A Mechanical Shaking Machine
Thiefing needles with and without end flanges
Glass syringes with luer lock tip, 10 ml and 50 or 100 ml
Micro Syringes
100 to 200 mL Disposable Graduated Glass Bottles
A Slugging Compound
Bottle Test Step by Step Instructions
Step 1: Take and prepare emulsion samples
Centrifugation Basics
Step 2: Prepare and condition test emulsions
Step 3: Inject demulsifiers to test emulsions
Step 4: Apply agitation to test emulsions
Step 5: Settling and observation period
How to use non-numerical data making Qualitative Evaluations more reliable
Step 6: Top cut
Step 7: Mixed cut
Step 8: Report
The essentials of successful demulsifier selection